7/32 in 5.69 mm MONOCONDUCTOR CORROSION RESISTANT
- CONDUCTORS: Copper / Nickel Plated
- INSULATION: PFA
- ARMOR: Enhanced Corrosion Resistant / Alloy Steel/UNS-S31277
|
|
|
ENGLISH |
METRIC |
CONSTRUCTION CHARACTERISTICS
|
|
|
| Conductor - #18 AWG, 7 x .0159: |
|
dia.0.0475” |
1.207 mm |
| Wall Thickness: |
|
0.0303" |
0.768 mm |
| Insulation - OD: |
|
dia. 0.108" |
2.743 mm |
| Armor - Inner: 12 wires .031": |
|
dia. 0.162" |
4.115 mm |
| Outer: 18 wires .031": |
|
dia. 0.224" |
5.69 mm |
| |
|
|
|
MECHANICAL CHARACTERISTICS
|
|
|
| Weight in Air: |
|
97 lbs/kft |
144 kg/km |
| Weight in Water: |
|
80 lbs/kft |
119 kg/km |
| Breaking Strength (Ends Fixed): |
|
4,900 lbs |
2,223 kg |
| Average Wire Breaking Strength: |
|
|
|
| Inner Armor |
|
116 lbs |
0.52 kN |
| Outer Armor |
|
252 lbs |
1.12 kN |
| Working Load (Maximum): |
|
2,450 lbs |
1,111 kg |
| Temperature Rating (Maximum): |
|
500°F |
260°C |
| Suggested Minimum Sheave: |
|
dia. 14" |
356 mm |
| Outside Diameter: |
|
0.224” +0.005" -0.002" |
5.69 +0.127 mm -0.051 mm |
| Stretch Coefficient (Nominal): |
|
3.1 ft/kft/klb |
3.5 m/km/5kN |
| |
|
|
|
ELECTRICAL CHARACTERISTICS
|
|
|
| Voltage Rating: |
|
1,200 VDC |
1,200 VDC |
| D.C. Conductor Resistance at 68F (20C): |
|
6.7 Ω/kft |
21.98 Ω/km |
| D.C. Armor Resistance at 68F (20C): |
|
18.1 Ω/kft |
59.4 Ω/km |
| Capacitance Conductor-to-Armor: |
|
43 pF/ft |
141 pF/m |
| Insulation Resistance: |
|
1,500 Min MΩ*kf |
457 MΩ*km |
* Insulation is rated to 500 deg. F. Armor wires are rated to 425 deg. F. at "medium exposure" to H2S & CO2
>> View Product Spec Sheet
|