| |
|
|
9/32 in 7.31 mm MONOCONDUCTOR CORROSION RESISTANT
- CONDUCTORS: Copper / Nickel Plated
- INSULATION: PFA - 500 F
- ARMOR: Enhanced Corrosion Resistant / Alloy Steel/UNS S31277
|
|
|
ENGLISH |
METRIC |
CONSTRUCTION CHARACTERISTICS
|
|
|
| Conductor - #16 AWG, 19 x 0.0128": |
|
dia.0.064” |
1.626 mm |
| Wall Thickness: |
|
0.036" |
0.914 mm |
| Insulation - OD: |
|
dia. 0.136" |
3.454 mm |
| Armor - Inner: 12 wires .040": |
|
dia. 0.208" |
5.283 mm |
| Outer: 18 wires .040": |
|
dia. 0.288" |
7.315 mm |
| |
|
|
|
MECHANICAL CHARACTERISTICS
|
|
|
| Weight in Air: |
|
160 lbs/kft |
237 kg/km |
| Weight in Water: |
|
132 lbs/kft |
196 kg/km |
| Breaking Strength (Ends Fixed): |
|
7,800 lbs |
3,538 kg |
| Average Wire Breaking Strength: |
|
|
|
| Inner Armor |
|
314 lbs |
1.40 kN |
| Outer Armor |
|
314 lbs |
1.40 kN |
| Working Load (Maximum): |
|
3,900 lbs |
1,769 kg |
| Temperature Rating (Maximum): |
|
500°F |
260°C |
| Suggested Minimum Sheave: |
|
dia. 16" |
406 mm |
| Outside Diameter: |
|
0.288” +0.005" -0.002" |
7.32 +0.127 mm -0.051 mm |
| Stretch Coefficient (Nominal): |
|
2.0 ft/kft/klb |
2.25 m/km/5kN |
| |
|
|
|
ELECTRICAL CHARACTERISTICS
|
|
|
| Voltage Rating: |
|
1,500 VDC |
1,500 VDC |
| D.C. Conductor Resistance at 68F (20C): |
|
4.0 Ω/kft |
13.1 Ω/km |
| D.C. Armor Resistance at 68F (20C): |
|
14.5 Ω/kft |
45.9 Ω/km |
| Capacitance Conductor-to-Armor: |
|
54 pF/ft |
177 pF/m |
| Insulation Resistance: |
|
1,500 Min MΩ*kf |
457 MΩ*km |
* Insulation is rated to 500 deg. F. Armor wires are rated to 350 deg. F. at “medium exposure” to H2S & CO2
>> View Product Spec Sheet
|